Not in S (not in service), L/Gasket(gasket
leak), L/Body (body leak), NO CHECK (not inspected)
Memory
Total available registered trap
models : 2400 when shipped, (3600 possible). Call registered models
: max, 30 models per trap type
No. of steam traps that can be tested and survey data memorized
at one time : approximately 1700
Information iteams: 20. Model/Judgement/Temperature/Pressure/Inspection
Data/Application/Installation date/Connection, etc.
Display
16 digits X 2 lines, 5 X 7 Matrix
LCD
Steam Pressure Range
0.5~80§¸/§²G (0.5~80 barg)
Steam Trap Surface Temperature
0~350¡ÆC
Operating Temperature
0~40¡ÆC
Humidity Range
20~80¡ÆC RH
External Interface
RS232C (Maximum communication speed
: 19200 bps)
Power
* Main Battery : Ni-Cd 650 mAh.
Backup Battery : Lithium 850 mAh (Holds data for appox. 10 yrs)
Charger : Rapid 1 hr. charge (Special charger with protection against
overcharge)
Auto Power OFF : Auto Power off function if no operation for more
than 5 minutes (defaults to enabled, can set to disabled)
Resume : Yes (indicates trap No, when power went off). Battery Recondition
: Yes (do it before recharging)